          Home 油擴散式真空幫浦

           

          Vacuum Pump - Diffusion Pump – AX-65 / HS-2 / VHS-4 / VHS-6
           
           
           
           
          AX-65
          HS-2
          VHS-4
          VHS-6
           
          Pump Model
          AX-65
          HS-2
          VHS-4
          VHS-6
          Previous Model Number
          -
          0160
          0183
          184
          Speed, l/s (operating range)
           
           
           
           
          Air
          65
          160
          750
          1,550
          Helium & Hydrogen
          90
          200
          940
          1,930
          Maximum forepressure, Torr (mbar)
           
           
           
           
          No load
          0.75 (1.00)
          0.55 (0.72)
          0.65 (.86)
          0.65 (0.85)
          Full load
          0.60 (0.78)
          0.40 (0.52)
          0.55 (.73)
          0.55 (0.72)
          Maximum throughput,
           
           
           
           
          T-l/s (mbar-l/s) In operating range
          0.19 (0.25)
          0.60 (0.80)
          1.5 (2.0)
          2.4 (3.2)
          @ 1 x 10-2 Torr (1.3 x 10-2 mbar)
          0.30 (0.40)
          0.70 (0.93)
          2.5 (3.2)
          3.5 (4.5)
          Minimum recommended backing pump
          for maximum throughput, cfm (m3/hr)
          0.15 (0.25)
          5.0 (8.5)
          10 (17)
          17.0 (28.9)
          Backstreaming rate at inlet flange
          mg/cm2/min (standard cold cap)*
          2 x 10-4
          1 x 10-3
          5 x 10-4
          5 x 10-4
          Warmup time, minutes
          7
          15
          10
          10
          Cooldown time, minutes
          With quick cool coil, where applicable
          -
          10
          10
          10
          Fluid charge
          30cc
          100 cc
          300 cc
          500 cc
          Electrical requirements
          1 ph
          50/60 Hz
          90/115/165/220 V
          1 ph
          50/60 Hz
          120/240 V
          1 ph
          50/60 Hz
          120/208/240 V
          1 ph
          50/60 Hz
          120/208/240 V
          Power, Watts
          200/250
          450
          1450
          2200
          Cooling water, U.S. gpm (l/hr)
          at 60-80° F (15-26 °C)
          N/A
          0.1 (20)
          0.15 (30)
          0.25 (50)
           

           

          Vacuum Pump - Diffusion Pump – VHS-250 / VHS-10 / VHS-400 / HS-16
           
           
           
           
          VHS-250
          VHS-10
          VHS-400
          HS-16
           
          Pump Model
          VHS-250
          VHS-10
          VHS-400
          HS-16
          Previous Model Number
          0185
          0164
          Speed, l/s (operating range)
           
           
           
           
          Air
          2,125
          3,650
          4,500
          6,000
          Helium & Hydrogen
          2,660
          4,560
          5,625
          7,500
          Maximum forepressure, Torr (mbar)
           
           
           
           
          No load
          0.65 (.85)
          0.65 (.85)
          0.65 (.85)
          0.65 (.85)
          Full load
          0.55 (0.72)
          0.55 (0.72)
          0.55 (0.72)
          0.55 (.72)
          Maximum throughput,
           
           
           
          at 8100 W
          T-l/s (mbar-l/s) In operating range
          2.6 (3.5)
          6.3 (8.4)
          6.3 (8.4)
          9.5 (11.7)
          @ 1 x 10-2 Torr (1.3 x 10-2 mbar)
          3.5 (4.5)
          7.5 (10.0)
          7.5 (10.0)
          11.5 (15.3)
          Minimum recommended backing pump
          for maximum throughput, cfm (m3/hr)
          17.0 (28.9)
          30 (51)
          30 (51)
          80 (136)
          Backstreaming rate at inlet flange
          mg/cm2/min (standard cold cap)*
          5 x 10-4
          5 x 10-4
          1 x 10-3
          1.5 x 10-3
          Warmup time, minutes
          15
          15
          30
          45
          Cooldown time, minutes
          With quick cool coil, where applicable
          10
          25
          25
          48
          Fluid charge
          1,000 cc
          1,000 cc
          3 U.S. qts.
          5 U.S. qts.
          Electrical requirements
          3 ph
          50/60 Hz
          120/208/240 V
          3 ph
          50/60 Hz
          208/240/380/480 V
          3 ph
          50/60 Hz
          208/240/380/480 V
          3 ph
          50/60 Hz
          240/415/480 V
          Power, Watts
          2200
          4400
          4400
          8100/9600
          Cooling water, U.S. gpm (l/hr)
          at 60-80° F (15-26 °C)
          0.25 (50)
          0.40 (80)
          0.40 (80)
          1.5 (300)
           

           

          Vacuum Pump - Diffusion Pump – HS-20 / HS-32 / HS-35
           
           
           
           
          HS-20
          HS-32
          HS-35
           
           
           
           
          Pump Model
          HS-20
          HS-32
          NHS-35
          Previous Model Number
          0165
          0167
          0169
          Speed, l/s (operating range), Air
          10,000
          17,300
          28,000
          Helium & Hydrogen
          12,500
          21,625
          35,000
          Maximum forepressure, Torr (mbar)
           
           
           
          No load
          0.65 (.85)
          0.50 (.65)
          0.55 (.71)
          Full load
          0.55 (.72)
          0.35 (.45)
          0.40 (.52)
          Maximum throughput,
           
           
           
          T-l/s (mbar-l/s) In operating range
          12.5 (16.7)
          30 (40)
          25 (33)
          @ 1 x 10-2 Torr (1.3 x 10-2 mbar)
          18 (23.4)
          35 (45.5)
          35 (45.5)
          Minimum recommended backing pump
          for maximum throughput, cfm (m3/hr)
          100 (170)
          300 (510)
          300 (510)
          Backstreaming rate at inlet flange
          mg/cm2/min (standard cold cap)*
          1.5 x 10-3
          7 x 10-4
          5 x 10-4
          Warmup time, minutes
          60
          60
          -
          Cooldown time, minutes
          With quick cool coil, where applicable
          85
          180
          180
          Fluid charge
          3 U.S. gal.
          (4.7 liters)
          3 U.S. gal.
          (11.3 liters)
          3 U.S. gal.
          (11.3 liters)
          Electrical requirements
          3 ph, 50/60 Hz
          240/415/480 V
          3 ph, 50/60 Hz
          240/415/480 V
          3 ph, 50/60 Hz
          240/415/480 V
          Power, Watts
          12000
          24000
          24000
          Cooling water, U.S. gpm (l/hr)
          at 60-80° F (15-26 °C)
          1.5 (300)
          4.0 (800)
          4.0 (800)
           